INTEGRA 1.06 firmware
SATEL launches a new 1.06 firmware version for INTEGRA range of intruder alarm control panels. This upgrade provides support for both newly introduced and upgraded expansion devices. The new firmware provides a range of useful features as well, which includes easy automation control functions, or new diagnostic functions for installers. The most important changes for the installers and end users are as follows:
Expansion modules:
- support for INT-RS module. The module enables reporting via dedicated external unit, integration with other systems (like home automation), or communication with a PC running GUARDX software (just like the RS232 port in the LCD keypad)
- support for ABAX ACU-100 firmware 1.07 and 2.0. These devices enable support for new wireless units like the pet immune APD-100, and APT-100 remote control keyfobs
- new option for access control modules (INT-S-GR, INT-S-BL, INT-SK-GR, INT-SCR-BL, INT-SZ-GR, INT-SZ-BL, INT-SZK-GR, CA-64 SR and CA-64 SR - all with the latest firmware upgrades) on fire alarm emergency door opening
Arming:
- new arming mode: full arm with bypass. In this mode, the partition will arm fully with "Bypass when no exit" zones bypassed. This mode can be used for arming with LCD keypads, partition keypads, zones and timers
- quick arm for LCD keypads and partition keypads have been changed: by pressing "1" and "#" the partition will arm in "Full arm with bypass" mode
- when arming with LCD keypad, if a "Priority" zone is triggered, one have a possibility to bypass it with "4" key during triggered zones review
Controlling:
- easy controlling with LCD keypad that does not require entering a code is introduced. By pressing "8" and "#", one can enter a "Controlling" menu
- free output time programming for "MONO switches" when controlling via LCD keypad
- possibility to turn off each control output via LCD keypad (regardless of output time) by pressing any numeric button when in "Controlling" menu
Diagnostics:
- individual zone testing in service mode. Zone triggering can be indicated not only in the keypad, but also can be signalled on selected output, e.g. with a system siren
- individual output testing in service mode
- proximity card testing feature, allowing to check card number and to figure out card assigned card user
- system battery test on demand